सभी किताबें

पेशेवर

1 Markets I: The Ecosystem and Exchange-Traded Marketsबाज़ार ऑनलाइन 2 Markets II: Rates, FX and Creditबाज़ार ऑनलाइन 3 Markets III: Commodities, Energy and Cryptoबाज़ार ऑनलाइन 4 Quantitative Methodsविधियाँ ऑनलाइन 5 Derivatives and Volatilityडेरिवेटिव्स ऑनलाइन 6 Rates, Credit, XVA and Riskब्याज दरें, क्रेडिट और जोखिम ऑनलाइन 7 Research Craft: Predictors, Backtests, Measurement, Portfoliosअनुसंधान ऑनलाइन 8 Strategies I: Equities and Futuresरणनीतियाँ ऑनलाइन 9 Strategies II: Volatility, Relative Value, Macro and the Bank Desksरणनीतियाँ ऑनलाइन 10 Microstructure and Executionनिष्पादन ऑनलाइन 11 Market Making and High-Frequency Tradingमार्केट मेकिंग ऑनलाइन 12 Machine Learning for Marketsमशीन लर्निंग ऑनलाइन 13 Low-Latency Softwareतकनीक ऑनलाइन 14 Networks, Hardware and Trading Infrastructureतकनीक ऑनलाइन 15 Research, Data and Risk Platformsतकनीक ऑनलाइन 16 The Desk and the Firmफ़र्म ऑनलाइन 17 The Industry: Firms, Roles and Careersकरियर ऑनलाइन 18 Interviews I: Maths, Probability and Speedकरियर ऑनलाइन 19 Interviews II: Markets, Trading Games and the Final Roundकरियर ऑनलाइन 20 Interviews III: Codeकरियर ऑनलाइन
ऐप्स परिचय Coach लॉग इन पढ़ना शुरू करें

Quantitative Finance · शब्दावली

Hot path क्या है?

Definition 1.3 Low-Latency Software · अध्याय 1 — Where Latency Comes From

The hot path of a trading system is the sequence of code executed between a triggering market event and the resulting order: the code whose duration is the tick-to-trade latency. Everything else (logging to disk, reporting, risk aggregation, configuration) runs off the hot path, on other threads or at other times.

उदाहरण

Example 1.4 (Light in fibre, bits on the wire)

A standard single-mode fibre has an effective group index of about 1.462 at a wavelength of 1 550 nm (a manufacturer’s specification sheet): light in it covers a metre in 1.462/c=4.88 ns1.462/c = 4.88\,\mathrm{n}\mathrm{s}, so the 30 metres of cable between a server and an exchange’s switch inside one data centre cost about 146 ns146\,\mathrm{n}\mathrm{s} each way. Putting a frame on the wire takes its length in bits divided by the line rate, plus 20 bytes of preamble, start delimiter and inter-frame gap: a minimal 64-byte frame occupies a 10 Gb/s link for 84×8/10=67.2 ns84 \times 8 / 10 = 67.2\,\mathrm{n}\mathrm{s} and a 25 Gb/s link for 26.9 ns26.9\,\mathrm{n}\mathrm{s}. A software path of a few microseconds is therefore dominated by computation and by the operating system, not by physics, until it is very good.

अध्याय में पढ़ें →