1 Markets I: The Ecosystem and Exchange-Traded Marketsबाज़ार ऑनलाइन 2 Markets II: Rates, FX and Creditबाज़ार ऑनलाइन 3 Markets III: Commodities, Energy and Cryptoबाज़ार ऑनलाइन 4 Quantitative Methodsविधियाँ ऑनलाइन 5 Derivatives and Volatilityडेरिवेटिव्स ऑनलाइन 6 Rates, Credit, XVA and Riskब्याज दरें, क्रेडिट और जोखिम ऑनलाइन 7 Research Craft: Predictors, Backtests, Measurement, Portfoliosअनुसंधान ऑनलाइन 8 Strategies I: Equities and Futuresरणनीतियाँ ऑनलाइन 9 Strategies II: Volatility, Relative Value, Macro and the Bank Desksरणनीतियाँ ऑनलाइन 10 Microstructure and Executionनिष्पादन ऑनलाइन 11 Market Making and High-Frequency Tradingमार्केट मेकिंग ऑनलाइन 12 Machine Learning for Marketsमशीन लर्निंग ऑनलाइन 13 Low-Latency Softwareतकनीक ऑनलाइन 14 Networks, Hardware and Trading Infrastructureतकनीक ऑनलाइन 15 Research, Data and Risk Platformsतकनीक ऑनलाइन 16 The Desk and the Firmफ़र्म ऑनलाइन 17 The Industry: Firms, Roles and Careersकरियर ऑनलाइन 18 Interviews I: Maths, Probability and Speedकरियर ऑनलाइन 19 Interviews II: Markets, Trading Games and the Final Roundकरियर ऑनलाइन 20 Interviews III: Codeकरियर ऑनलाइन
ऐप्स परिचय Coach लॉग इन पढ़ना शुरू करें

Quantitative Finance · शब्दावली

Recovery time objective, recovery point objective क्या है?

अन्य नाम: recovery time objective · recovery point objective

Definition 28.4 Networks, Hardware and Trading Infrastructure · अध्याय 28 — Disaster Recovery and Regulatory Requirements

A recovery time objective is the longest a system may take, from its loss, to be back in service; a recovery point objective is the most recent data the firm may lose, measured as the time between the last change the recovery site holds and the moment of loss.

Simulation: the recovery-time distributions of the hot and warm designs, against the two-hour line. The hot design resumes within two hours in 99.2% of simulated recoveries (median 64 minutes); the warm one in 20.3% (median 148). Data: fig_dr.py, nw_dr.rto_hist().
Figure 28.1. Simulation: the recovery-time distributions of the hot and warm designs, against the two-hour line. The hot design resumes within two hours in 99.2% of simulated recoveries (median 64 minutes); the warm one in 20.3% (median 148). Data: fig_dr.py, nw_dr.rto_hist().