সব বই

পেশাদার

1 Markets I: The Ecosystem and Exchange-Traded Marketsবাজার অনলাইন 2 Markets II: Rates, FX and Creditবাজার অনলাইন 3 Markets III: Commodities, Energy and Cryptoবাজার অনলাইন 4 Quantitative Methodsপদ্ধতি অনলাইন 5 Derivatives and Volatilityডেরিভেটিভস অনলাইন 6 Rates, Credit, XVA and Riskসুদহার, ঋণ ও ঝুঁকি অনলাইন 7 Research Craft: Predictors, Backtests, Measurement, Portfoliosগবেষণা অনলাইন 8 Strategies I: Equities and Futuresকৌশল অনলাইন 9 Strategies II: Volatility, Relative Value, Macro and the Bank Desksকৌশল অনলাইন 10 Microstructure and Executionএক্সিকিউশন অনলাইন 11 Market Making and High-Frequency Tradingমার্কেট মেকিং অনলাইন 12 Machine Learning for Marketsমেশিন লার্নিং অনলাইন 13 Low-Latency Softwareপ্রযুক্তি অনলাইন 14 Networks, Hardware and Trading Infrastructureপ্রযুক্তি অনলাইন 15 Research, Data and Risk Platformsপ্রযুক্তি অনলাইন 16 The Desk and the Firmপ্রতিষ্ঠান অনলাইন 17 The Industry: Firms, Roles and Careersক্যারিয়ার অনলাইন 18 Interviews I: Maths, Probability and Speedক্যারিয়ার অনলাইন 19 Interviews II: Markets, Trading Games and the Final Roundক্যারিয়ার অনলাইন 20 Interviews III: Codeক্যারিয়ার অনলাইন
অ্যাপ পরিচিতি Coach সাইন ইন পড়া শুরু করো

বইগুলো এখনো বাংলা ভাষায় পাওয়া যায় না — ইংরেজি সংস্করণ দেখানো হচ্ছে।

Chemistry · পরিভাষা

Stopped flow, flash photolysis কী?

অন্য নাম: stopped-flow method · flash photolysis

Definition 13.25 University Chemistry — Year 3 · অধ্যায় 13 — Complex Kinetics: Chains, Enzymes and Oscillations

The stopped-flow method mixes two reactant solutions in about a millisecond by driving them through a mixer into an observation cell, then stops the flow and records the absorbance or fluorescence. Flash photolysis creates a reactive species by a short intense light pulse and follows its reactions with a second, delayed light beam.

A stopped-flow apparatus. The drive pushes two syringes; the solutions meet in the mixer and fill the observation cell within about a millisecond; the plunger of the stop syringe hits a block, the flow stops, and the detector records the reaction of the freshly mixed solution.
A stopped-flow apparatus. The drive pushes two syringes; the solutions meet in the mixer and fill the observation cell within about a millisecond; the plunger of the stop syringe hits a block, the flow stops, and the detector records the reaction of the freshly mixed solution.
A stopped-flow burst trace (data of the weekend problem): the first product of a two-step enzyme appears in a fast burst followed by a straight line; the dashed line extrapolates the steady state back to t = 0.
A stopped-flow burst trace (data of the weekend problem): the first product of a two-step enzyme appears in a fast burst followed by a straight line; the dashed line extrapolates the steady state back to t=0t = 0.
প্রসঙ্গসহ পড়ো →